EO: 1.1 – 1.9 FUN 1 EO: 1.1 FUN 1 EO: 1.2 FUN 1 EO: 1.3 FUN 1 EO: 1.4 FUN 1 EO: 1.5 FUN 1 EO: 1.6 FUN 1 EO: 1.7 & 1.8 FUN 1 EO: 1.9 EO: 1.10 – 1.19 FUN 1 EO: 1.10 FUN 1 EO: 1.11 FUN 1 EO: 1.12 FUN 1 EO: 1.13 FUN 1 EO: 1.14 FUN 1 EO: 1.15 FUN 1 EO: 1.16 FUN 1 EO: 1.17 FUN 1 EO: 1.18 FUN 1 EO: 1.19 EO: 1.20- 1.30 FUN 1 EO: 1.20 FUN 1 EO: 1.21 & 1.22 FUN 1 EO: 1.23 & 1.24 FUN 1 EO: 1.25 FUN 1 EO: 1.26 FUN 1 EO: 1.27 FUN 1 EO: 1.28 FUN 1 EO: 1.29 & 1.30 EO: 1.31- 1.39 FUN 1 EO: 1.31 & 1.32 FUN 1 EO: 1.33 & 1.34 FUN 1 EO: 1.35 & 1.36 FUN 1 EO: 1.37 FUN 1 EO: 1.38 FUN 1 EO: 1.39 EO: 1.40- 1.49 FUN 1 EO: 1.40 FUN 1 EO: 1.41 FUN 1 EO: 1.42 FUN 1 EO: 1.43 FUN 1 EO: 1.44 FUN 1 EO: 1.45 & 1.46 FUN 1 EO: 1.47 FUN 1 EO: 1.48 FUN 1 EO: 1.49 EO: 1.50- 1.62 FUN 1 EO: 1.50 FUN 1 EO: 1.51 FUN 1 EO: 1.52 FUN 1 EO: 1.53 FUN 1 EO: 1.54 FUN 1 EO: 1.55 FUN 1 EO: 1.56 FUN 1 EO: 1.57 FUN 1 EO: 1.58 FUN 1 EO: 1.59 FUN 1 EO: 1.60 FUN 1 EO: 1.61 FUN 1 EO: 1.62 Menu EO: 1.1 – 1.9 FUN 1 EO: 1.1 FUN 1 EO: 1.2 FUN 1 EO: 1.3 FUN 1 EO: 1.4 FUN 1 EO: 1.5 FUN 1 EO: 1.6 FUN 1 EO: 1.7 & 1.8 FUN 1 EO: 1.9 EO: 1.10 – 1.19 FUN 1 EO: 1.10 FUN 1 EO: 1.11 FUN 1 EO: 1.12 FUN 1 EO: 1.13 FUN 1 EO: 1.14 FUN 1 EO: 1.15 FUN 1 EO: 1.16 FUN 1 EO: 1.17 FUN 1 EO: 1.18 FUN 1 EO: 1.19 EO: 1.20- 1.30 FUN 1 EO: 1.20 FUN 1 EO: 1.21 & 1.22 FUN 1 EO: 1.23 & 1.24 FUN 1 EO: 1.25 FUN 1 EO: 1.26 FUN 1 EO: 1.27 FUN 1 EO: 1.28 FUN 1 EO: 1.29 & 1.30 EO: 1.31- 1.39 FUN 1 EO: 1.31 & 1.32 FUN 1 EO: 1.33 & 1.34 FUN 1 EO: 1.35 & 1.36 FUN 1 EO: 1.37 FUN 1 EO: 1.38 FUN 1 EO: 1.39 EO: 1.40- 1.49 FUN 1 EO: 1.40 FUN 1 EO: 1.41 FUN 1 EO: 1.42 FUN 1 EO: 1.43 FUN 1 EO: 1.44 FUN 1 EO: 1.45 & 1.46 FUN 1 EO: 1.47 FUN 1 EO: 1.48 FUN 1 EO: 1.49 EO: 1.50- 1.62 FUN 1 EO: 1.50 FUN 1 EO: 1.51 FUN 1 EO: 1.52 FUN 1 EO: 1.53 FUN 1 EO: 1.54 FUN 1 EO: 1.55 FUN 1 EO: 1.56 FUN 1 EO: 1.57 FUN 1 EO: 1.58 FUN 1 EO: 1.59 FUN 1 EO: 1.60 FUN 1 EO: 1.61 FUN 1 EO: 1.62 EO: 1.1 – 1.3 FUN 2 EO: 1.1 FUN 2 EO: 1.2 FUN 2 EO: 1.3 EO: 1.4a – 1.4d FUN 2 EO: 1.4-a FUN 2 EO: 1.4-b FUN 2 EO: 1.4-c FUN 2 EO: 1.4-d EO: 1.4e – 1.4h FUN 2 EO: 1.4-e FUN 2 EO: 1.4-f FUN 2 EO: 1.4-g FUN 2 EO: 1.4-h EO: 1.4i – 1.5 FUN 2 EO: 1.4-i FUN 2 EO: 1.4-j FUN 2 EO: 1.4-k FUN 2 EO: 1.4-l FUN 2 EO: 1.5 Menu EO: 1.1 – 1.3 FUN 2 EO: 1.1 FUN 2 EO: 1.2 FUN 2 EO: 1.3 EO: 1.4a – 1.4d FUN 2 EO: 1.4-a FUN 2 EO: 1.4-b FUN 2 EO: 1.4-c FUN 2 EO: 1.4-d EO: 1.4e – 1.4h FUN 2 EO: 1.4-e FUN 2 EO: 1.4-f FUN 2 EO: 1.4-g FUN 2 EO: 1.4-h EO: 1.4i – 1.5 FUN 2 EO: 1.4-i FUN 2 EO: 1.4-j FUN 2 EO: 1.4-k FUN 2 EO: 1.4-l FUN 2 EO: 1.5 FUN 2 EO: 1.4-b 1 / 10 What is the primary material the reactor vessel is constructed from? Stainless steel Carbon steel Aluminum Manganese molybdenum steel 2 / 10 How many steam generators and reactor coolant pumps does a two-loop Westinghouse plant possess? Three steam generators and two reactor coolant pumps Three steam generators and three reactor coolant pumps Two steam generators and two reactor coolant pumps Two steam generators and three reactor coolant pumps 3 / 10 Which system acts as the second barrier to prevent the release of fission products into the environment? Reactor Coolant System Steam Generating System Heat Transfer System Fission Product Containment System 4 / 10 The highest radiological concern during Fuel Moves is due to: Potential for low contamination levels No radiological concerns during Fuel Moves Medium Radiation levels regardless of fuel positioning High / Locked or Very High Radiation levels if fuel is brought too close to the surface of the water or if irradiated fuel is brought out of the water 5 / 10 In the context of the Reactor Coolant System, which component consists of the reactor vessel, the steam generators, the reactor coolant pumps, a pressurizer, and the connecting piping? Secondary system Quaternary system Primary system Tertiary system 6 / 10 What radiological concerns are associated with CEDM work? No radiological concerns associated with CEDM work Low Radiation Area and potential for low contamination levels High Radiation Area and potential for high contamination levels Medium Radiation Area and potential for medium contamination levels 7 / 10 Which part of the Reactor Vessel and Internals contains the fuel assemblies and the equipment to align and support the weight of the fuel assemblies? Core barrel Top head Upper guide structure Lower core support area 8 / 10 Which component in the Reactor Coolant System ensures the water is kept from boiling? Steam Generator Reactor Coolant Pumps Pressurizer Reactor Vessel 9 / 10 What is the primary function of the Reactor Coolant System (RCS)? To cool the reactor core by transferring the heat generated in the core to the Steam Generators To facilitate the movement of reactor coolant To contain all of the fission products To increase the temperature of the reactor core 10 / 10 During a Core offload and reload, what are the potential radiological concerns? No radiological concerns are associated with a Core offload and reload High dose rates, high contamination levels, discrete radioactive particles or airborne Low dose rates, low contamination levels, no discrete radioactive particles Medium dose rates, medium contamination levels, potential for airborne Your score is Share your results with your friends!! LinkedIn Facebook Twitter VKontakte Restart quiz PreviousFUN 2 EO: 1.4-bNext